Direct Type Relief Valve
Feature
• Remote-control series can be used for remote control and multi-stage pressure control.
• Direct-control series can be used as a safety valve in small flow system.
Model Description
D | G | -01 | -3 |
Model/ Series |
Installation Type |
Thread Code Size (Inch) |
Pressure Adjustment Range Kgf/c㎡ |
Remote Control |
G : Sub-Plate Mounting T : Threaded Connection |
01 : 1/8" |
1 : 10-70 2 : 35-140 3 : 70-210 |
Direct Type |
G : Sub-Plate Mounting T : Threaded Connection |
02 :1/4" |
Specification
Model/Type |
Operating Pressure (Max.)Kgf/c㎡ |
Operating Pressure (Max.)Kgf/c㎡ |
Rated Flow (Max.)L/min |
|
Remote Control | D※-01-1 |
250 |
7-70 |
2 |
D※-01-2 | 35-140 | |||
D※-01-3 | 70-210 | |||
Direct Type | D※-02-1 | 250 | 7-70 | 16 |
D※-02-2 | 35-140 | |||
D※-02-3 | 70-210 |